Emerson Process Management 2500 Home Security System User Manual


 
3 Mounting and sensor wiring for
remote core processor with remote
sensor installations
Topics covered in this chapter:
Mounting the transmitter to a DIN rail
Mount the remote core processor
Prepare the 4-wire cable
Wire the transmitter to the remote core processor
Prepare the 9-wire cable
Wire the remote core processor to the sensor using jacketed cable
Wire the remote core processor to the sensor using shielded or armored cable
Ground the flowmeter components
3.1 Mounting the transmitter to a DIN rail
The transmitter is designed to be mounted on a 35 mm DIN rail. The DIN rail must be
grounded.
Mounting the transmitterFigure 3-1:
A
B
C
A. Spring clamp
B. DIN rail
C. Spring clamp release loop
3.1.1
Mounting multiple transmitters
If the ambient temperature is above 113 °F (45 °C) and you are mounting multiple
transmitters, mount the transmitters so they are at least 0.33 in (8.5 mm) apart.
Mounting and sensor wiring for remote core processor with remote sensor installations
12 Micro Motion
®
Model 1500 and Model 2500