Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
Installation Manual
308014EN, Edition 4
May 2013
3 Put the antenna and flange
assembly on the tank nozzle
and tighten the flange screws.
4 Put the TRL/2 adapter on top of
the antenna feeder.
Note that there is a guide pin
inside the TRL/2 adapter that
fits the groove on the outside of
the antenna feeder.
Tighten the nut firmly.
5 Mount the Waveguide Unit into
the base of the Transmitter
Head. On one end of the Wave-
guide Unit there are two screws
with washers. Mount the Wave-
guide Unit with this end into the
base of the Transmitter Head.
Enter the stop screws and
tighten.
3950_Flange_Step3.eps
TRL/2 adapter
Antenna
feeder
3950_Flange_Step4.eps
Nut
Waveguide
Unit
Stop
screws x 2
3950_Flange_Step5.eps