2-3
Rosemount Tank Radar REX
Chapter 2 Safety
Installation Manual
308014EN, Edition 4
May 2013
2.3 European ATEX Directive Information
2.3.1 Radar Unit
The REX Radar Unit has been certified to comply with Directive 94/9/EC
of the European Parliament and the Council as published in the Official
Journal of the European Communities No. L 100/1.
Figure 2-1. Certification label ATEX for the 2015 Radar Unit (used in
3900 series radar tank gauges).
The following information is provided as part of the label of the radar unit:
• Name and address of the manufacturer
(Rosemount Tank Radar AB).
• CE Conformity Marking
• Complete model number
• The serial number of the device
• Year of construction
• Marking for explosion protection:
• Ex d IIB Gb T6 (-40 °C Ta +70 °C)
• Baseefa(2001) ATEX certificate number: Baseefa03ATEX0071X
Special Conditions for Safe Use (X):
• The Type TH2015-2019 Radar Units are not to be mounted
directly on to a tank.
• For replacement purposes the cover fastening screws are to be of
minimum grade A4-80 stainless steel.
• The permanently attached cables are to be suitably terminated
and protected against impact.