Emerson CF980MBX 00 Fan User Manual


 
9
HANGER
BRACKET
OUTLET BOX
RECEIVER
CEILING
COVER
Figure 16
YELLOW RECEIVER
WIRE
DO NOT USE
DOWNROD
WHITE SUPPLY WIRE
BLACK FAN WIRE
SW105
RECEIVER
TO
110V
SUPPLY
WHITE FAN WIRE
BLUE RECEIVER WIRE
BLUE FAN WIRE
BLACK
SUPPLY
WHITE RECEIVER WIRE
BLACK RECEIVER WIRE
BLACK/WHITE RECEIVER
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
4. Carefully turn the wires upward and insert them up
through the open side of the hanger bracket and
into the outlet box. Push the green and white wires
into one side of the outlet box; push the black, blue
and yellow wires into the other side of the outlet
box.
Figure 15
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
WARNING
5. Screw the two 1-1/4” threaded studs (supplied)
into the tapped holes in the hanger bracket
(Figure 17).
6. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 17).
7. Secure the ceiling cover in place by sliding
lockwashers (supplied) over the threaded studs and
installing the two knurled knobs (supplied).
(Figure 17.) Tighten the knurled knobs securely until
the ceiling cover fits snugly against the ceiling and the
hole in the ceiling cover is clear of the downrod. Your
fan is now wired to be turned on and off from the fan
switch.
1-1/4"
THREADED
STUD
CEILING
COVER
KNURLED KNOB
LOCKWASHER
Figure 17