4. Install a wall control in the wall box
containing the “hot” wire first. Connect
one black wire of the wall control to the
“hot” wire. Securely connect wires with
wire connectors supplied.
5. Connect the other black wire of the wall
control to both remaining traveler
wire(s) in the wall box and secure with
wire connector supplied.
NOTE: Retrofit 3-way installations are
likely to include two traveler wires
between the two wall boxes. In new
construction, only one traveler wire is
required.
3-WAY WIRlNG DIAGRAM:
NEW CONSTRUCTION
6. Place wall control into wall box. Screw
in place and install decorator style
faceplate (included).
7. Next, install the other wall control into
the wall box containing the “load” wire.
Connect one black wire of the wall
control to the traveler wire(s) already
connected to the black wire (in the
other wall box). Secure with wire
connectors supplied.
8. Connect the other black wire of the wall
control to the “load” (black) wire and
secure with wire connector supplied.
9. Place the second wall control into the
wall box. Screw in place and install
decorator style faceplate (included).
Leave switch in “OFF” mode until fan
installation is completed.
10. Refer to “How to Assemble Your
Ceiling Fan” section to complete the
assembly of your ceiling fan.
HOT
BLACK
FAN/LIGHT
WALL
CONTROL
TRAVELER
WIRE
BLK
BLK
LOAD
BLACK
GROUND
NEUTRAL
REMOTE CONTROL
RECEIVER LOCATED
WITHIN THE CEILING
COVER
EMERSON
®
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ONOFF
HI
MED
LOW
FAN OFF
LIGHT
ONOFF
Figure 4
7
STANDARD WIRING FOR
EXISTING 3-WAY
CONTROLS
3-WAY WIRING DIAGRAM:
RETROFIT
HOT
BLK
TRAVELER WIRES
BLACK
LOAD
EXISTING
WALL CONTROL
HOT
BLK
TRAVELER WIRES
BLACK
LOAD
EXISTING
WALL CONTROL
Figure 5
1. Mount blade flanges to fan blades
using three #10-32 x 5/16” pan head
blade screws and three #10 flat blade
washers (supplied in loose parts bag)
(Figure 6).
How to Assemble Your
Ceiling Fan
To reduce the risk of personal injury, do
not bend the blade flanges when
installing the flanges, balancing the
blades, or cleaning the fan. Do not insert
foreign objects between rotating fan
blades.
!
WARNING
Turning off wall switch is not sufficient.
To avoid possible electrical shock, be
sure electricity is turned off at the main
fuse or circuit breaker box before wiring.
All wiring must be in accordance with
National and Local codes and the ceiling
fan must be properly grounded as a
precaution against possible electrical
shock.
!
WARNING