Emerson CF943 Fan User Manual


 
Installation of Wall Control
SINGLE-POLE
INSTALLATION
(Figure 2)
1. Disconnect power at circuit breaker or
remove fuse.
2. Remove faceplate and screws from
existing wall switch. Pull switch out
from the wall box. Determine the “hot”
wire and the “load” wire and disconnect
these wires from switch. Do not attempt
to disconnect any wires not already
connected to existing switch.
3. Before installing wall control, place wall
control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.
4. Connect one black wire of wall control
to the “hot” wire in the wall box.
Securely connect wires with wire
connectors supplied (Figure 3).
5. Connect the other black wire of wall
control to the “load” (black) wire in wall
box. Securely connect wires with wire
connector supplied.
6. Screw wall control into wall box and
install decorator style faceplate
(included). Leave wall control in “OFF”
mode until fan installation is completed.
7. Refer to page 7 to complete the ceiling
fan installation.
3-WAY INSTALLATION
(On fan controlled by two different wall
controls) (See Figures 4 and 5.)
1. Disconnect power at circuit breaker or
remove fuse.
2. At all wall box locations remove
faceplates and screws from existing
switches. Pull switches out from wall
boxes and determine which wall box
contains the “hot” lead and which wall
box contains the “load” wire. Also,
identify traveler wires which are
common to both wall boxes.
Disconnect wires from existing
switches only. Do not attempt to
disconnect any wires not already
connected to existing switches.
3. Before installing wall control, place wall
control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ONOFF
BLACK
BLK
HOT
FAN/LIGHT
WALL
CONTROL
WALL
BOX
T
O
L
O
A
D
T
O
1
2
0
V
A
C
S
O
U
R
C
E
G
R
O
U
N
D
Figure 3
6
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ONOFF
FAN/LIGHT
WALL CONTROL
HOT BLK
NEUTRAL
BLACK
GROUND
LOAD
BLACK
REMOTE CONTROL
RECEIVER LOCATED
WITHIN THE CEILING
COVER
Figure 2
Turning off wall switch is not sufficient.
To avoid possible electrical shock, be
sure electricity is turned off at the main
fuse or circuit breaker box before wiring.
All wiring must be in accordance with
National and Local codes and the ceiling
fan must be properly grounded as a
precaution against possible electrical
shock.
!
WARNING
Do not connect any neutral (white) wire to
this control. Incorrect wiring will damage
this control.
!
WARNING
Do not connect any neutral (white) wire to
this control. Incorrect wiring will damage
this control.
!
WARNING