Emerson 1F97-391 Thermostat User Manual


 
18
Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTS
1 EMR
(ON)
OFF
2 SET CYCL HEAT
(05)
02 - 40
Adjusts heat anticipation value (2 through 40)
See page 20
3 SET CYCL COOL
(12)
09 - 40
4 COOL FAN DELA OFF
(01)
01 - 127
5 COOL FAN DELA ON
(04)
01 - 05
6 COMP LOCK
(OFF)
ON
7 SYSTEM
(HEAT-OFF-COOL-AUTO)
HEAT-OFF,
COOL-OFF,
HEAT-OFF-COOL
Selects system switch choices for heat only,
cool only, heat/cool or automatic changeover
See page 21
Selects EMR option ON or OFF
See page 32
Adjusts cool anticipation value (9 through 40)
See page 20
Adjusts cool fan-off delay (1 through 127 sec.)
See page 20
Selects compressor lockout ON or OFF (see NOTE)
See page 21
Adjusts cool fan-on delay (1 through 5 sec.)
See page 20
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
BACK
CONFIGURACONFIGURA
CONFIGURACONFIGURA
CONFIGURA
TION MENUTION MENU
TION MENUTION MENU
TION MENU
The configuration menu allows you to set thermostat operating characteristics to your system or personal requirements.
To enter the menu, press TIME
FWD
and TIME
BACK
once at the same time. Press TIME
FWD
to advance through the
menu options. Press
arrow keys to change options. Either the installer or the operator may change shaded
options. We recommend that other options be set by the installer.