CONFIGURATION
The configuration menu allows you to set thermostat operating characteristics to your system or personal requirements.
To enter the menu, press TIME
FWD
and TIME
BACK
once at the same time. Press TIME
FWD
to advance through the
menu options. Press arrow keys to change options.
1
Step Press Button(s) Displayed Press or to select: COMMENTS Ref
(Factory Default) Page
0 F
(0)
5 LO to
5 HI
Adjusts temperature display higher or lower.
2 EMR
(ON)
OFF ON
ON L
Selects EMR option ON or OFF or ON L.
TIME
FWD
TIME
FWD
3
RH
(0)
20 LO to
20 HI
Adjusts humidity display.
TIME
F
W
D
4 DRY
(OFF)
LO or HI to OFF
To reduce or eliminate condensation during cold
weather. Use LO setting first, if condensation persists
use HI setting.
TIME
FWD
5
OPTM CMFT
(ON)
OFF
Enables improved dehumidification in cooling mode
if humidity is above setting.
TIME
F
W
D
6 OPTM DHUM
(OFF)
ON
Available if OPTM CMFT is ON. Provides extra
dehumidification if humidity is above setting. May
reduce temperature setpoint by up to 3 degrees.
TIME
FWD
User Configuration Menu
6
6
7
7
7
8