Emerson 1F95-391 Thermostat User Manual


 
9
Cool Fast.
(User menu, Step 11) This feature,
when set to ON, will bring the second
stage of cooling on any time you
manually lower the temperature three
or more degrees below room tempera-
ture. If COOL FAST is set to OFF,
the thermostat will delay the second
stage from 0 to 30 minutes based on
how well the first stage is keeping up
with your setting.
Optional Remote Temperature
Sense.
(User menu, Step 12,13,14,15) Up to
three remote sensors (F145-1328) can
be attached to this thermostat to sense
indoor temperature at locations away
from the thermostat. Each sensor may
be located as far as 300 feet away from
the thermostat. This is an excellent
feature if the thermostat is in a poor
location for sensing temperature or if
you want to install the thermostat in a
separate room to prevent tampering.
After installing and connecting the
remote sensor(s) to the thermostat, the
installer can enable each remote indoor
temperature sensor (A, B, and/or C).
When operating with remote sensor(s),
the thermostat will calculate an
average of the sensed temperatures in
all enabled sensor locations (A, B, C
and/or L), then display the average
temperature as the room temperature.
The temperature at each remote sensor
can be displayed by pressing the light
button twice within one second. With
the thermostat in program run or hold
mode. Temperatures at the outdoor and
indoor remote sensors will be
displayed with subsequent presses of
the light button in the following order
(if connected): outdoor sensor, sensor
L, A, B, C. You can also assign each
sensor different priorities during
different program periods. This allows
the system to maintain a comfortable
environment by giving higher priority
to occupied locations. At the same
time, giving lower priority to unoccu-
pied locations enhances efficient
system operation. EXAMPLE: Your
home has bedrooms on the upper level
and a guest bedroom on the main
level, along with the living room,
kitchen, etc. The thermostat (sensor L)
is located in the hall on the main level.
Remote sensors are located on the
upper level (sensor A) and the guest
bedroom (sensor B). The lower level
would be occupied in the DAY
and EVE periods. The upper level
would be occupied in the NHT and
MOR periods. With no guest in the
guest bedroom, the sensors could be
programmed as follows:
Configuration