EXCEL-FIRE GAS STOVE 8
DISTANCE DIAMETRE
20 pi 18GA
30 pi 16GA
40 pi 14 GA
50pi 12GA
REMOVE THE BLUE JUMPER BETWEEN TP & TPTH SCREWS ON THE GAS VALVE.
Optional blower
The blower control contains a variable speed switch and a thermal switch. When the stove is
operating, the thermal switch will turn on at 110° F, allowing the blower to operate. When the stove
cools to 90° F, the thermal switch turns off the blower in about 40 minutes. This prevents the
blower from operating when the stove is not in use.
The blower not only helps circulate air throughout the room, it also increases the heat output and
efficiency of the EXCEL-FIRE.
Blower electrical connection
Install the blower to the back of the stove using the 4 mounting screws. Than connect the two wires
to the motors connectors.
If you wish to make a direct electrical connection to the blower without using the six-foot cord
supplied, route a 120 volt, 60 Hz electrical power supply line to the same location. Remove the
power cord and connect the 120V line as per the following procedure:
• Unscrew the speed control unit and pull a few inches away from the junction box
• Unscrew the two marr connectors attached to the cord (P) and the cord ground
• Remove the cord and route the supply line through the same holes
• Make the electrical connection with the same wires the cord was attached to
• Screw the ground wire to the junction box (G)
• Screw the speed control unit back in place
P
P
G
CONNECT THE POWER LINE TO THE SAME
WIRES THE CORD WAS CONNECTED TO (P)
SPEED CONTROL
JUNCTION BOX
NOTE: If you prefer to use the six-foot cord supplied by Drolet, just connect it to a 120V outlet.