EXCEL-FIRE GAS STOVE 13
Pilot assembly
Adjusting air shutter (Venturi)
The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating
the appliance for half an hour or so the flames should have turned a nice yellow colour. However,
in higher altitudes you may find a smudging up of the glass after a few days. The shutter should
then be adjusted open in 1/16” increments until the glass stays clear. If the flame does not turn
yellow the air shutter should be closed until the flame just turns yellow. To access the shutter you
need to remove the glass front, the logs and grate. Lift out the hearth surrounding the burner and
the shutter will be exposed underneath. Loosen the retaining screw 1 turn before attempting to
move the shutter.
OPTIONS
ITEM DESCRIPTION Part no
• Wall thermostat kit AC05558
• 130 CFM blower kit with variable speed control AC05914
REPLACEMENT PARTS
ITEM DESCRIPTION Part no
• 6’’ stove pipe adapter SE9348
• Set of logs 5 AC05791
• Burner (natural gas or propane) SE09311-01
• Pyroceram Glass (19.446" x 11.737") SE09335-05
• 1/2″ dia. gasket for door 40020
• U gasket for glass 40005
• Blower 130 cfm 44070
• Variable speed control 44080
• Thermo-switch (for blower) 44044
• Gas valve (natural gas) SIT 49133
• Gas valve (propane) SIT 49126
• Pilot assembly (natural gas) SIT 49103
• Pilot assembly (propane) SIT 49106
• Piezo igniter 49128
• Burner orifice (natural gas #36) 9071
• Burner orifice (propane #52) 9071-01
• Thermocouple 49122
• Spill switch 44047
• Thermopile 49095