EXCEL-FIRE GAS STOVE 4
Burner
Naturel Gas Propane LP
Maximum Input, BTU/h (kW) minimum :
maximum :
20 000 (5,9)
30 000 (8,8)
20 000 (5,9)
26 000 (7,6)
Inlet Pressure INWC (kPa) minimum :
maximum :
5,0 (1,3)
7,0 (1,8)
11,0 (2,8)
14,0 (3,5)
Manifold Pressure INWC (kPa) minimum :
maximum :
1,8 (0,5)
3,5 (0,9)
7,0 (1,8)
10,0 (2,5)
Burner orifice ∅ :
#36 DMS #52 DMS
Injecteur du pilot ∅ :
#51 DMS #30 DMS
Air Shutter opening (in.) 1/4 open full open
Gas Valve SIT 820 Nova mV
Naturel Gas Propane LP
Millivolt Gas Valve :
Model SIT 0.820.634 Nova
mV
Model SIT 0.820.633 Nova
mV
Your stove is equipped with a sophisticated gas control valve, which will give you a safe use of your appliance. The
gas control valve SIT 820 Nova mV operates without electricity due to the energy given by the pilot flame and
captured by the thermo-generator. (also called thermopile). The admission of the gas fuel to the burner is done only
under safe conditions.
Pressure Adjustments
• Adjustments to the valve assembly must be performed by a qualified service person.
• The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa);
• The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less that ½ psi (3.5
kPa);
NATURAL GAS
The inlet supply or line pressure must be a minimum of 5 INWC and a maximum of 7 INWC. The orifice has a #36
hole.
ELEVATION (Canada) INPUT RATING
0-4500 ft (0-1400m) 30 000 BTU/h (8.8 kW)
Over 4500 ft (1400 m) + 30 000 BTU/h (8.8 kW) less 4% per 1000 ft (300 m)
or reduce manifold pressure by 0.25 INWC per 1000 ft (300 m)
ELEVATION (USA) INPUT RATING
0-2000 ft 30 000 BTU/h (8.8 kW)
Over 2000 ft Refer to local codes
GAZ PROPANE
The inlet supply or line pressure must be a minimum of 10.5” WC and a maximum of 12” WC. The orifice has a #52
hole.
ELEVATION (Canada) INPUT RATING
0-4500 pi (0-1400 m) 26 000 BTU/h (7.6kW)
4500 pi (1400m)+ 26 000 BTU/h (7.6kW) moins 4% par 1000 pi (300m)
or reduce manifold pressure by 1 INWC per 1000 ft
ELEVATION (USA) INPUT RATING
0-2000 ft 26 000 BTU/h (7.6kW)
Over 2000 ft Refer to local codes
NOTE : The input rating should always be checked when first running this appliance. To do this, verify inlet valve
pressure and manifold pressure,. Adjust manifold pressure to meet values range as indicated in burner
characteristics table.