Drolet SIT 0.820.634 Stove User Manual


 
ULTRA FLAME DIRECT VENT GAS STOVE 8
K. 72" Clearance to a mechanical air supply inlet
L. 84" Clearance above paved sidewalk or a paved driveway located on public property. A vent shall not terminate
directly above a sidewalk or paved driveway which is located between two single family dwellings and serves
both dwelling
M. 36" Clearance under veranda, porch, deck, or balcony. Only permitted if veranda, porch, deck, or balcony is fully
open on a minimum of 2 sides beneath the floor.
Local codes or regulations may require different clearances.
When the vent terminal is accessible, a certified guard shall be installed around the terminal. This guard is available as
an option, identified as part #E5480, for straight and corner terminals and #E5482 for the basement terminal
The vent terminal may not be recessed into the wall or siding.
The vent terminal shall not terminate:
Within 3 ft. of a building mechanical air supply.
Less than 12 inches from a perpendicular wall.
Under a window that pivots open.
In addition, in a structure with three walls and a roof, the vent terminal should not be installed if:
The minimum distance between the two sidewalls must be 72";
The roof exceed the walls by more than 24".
INSTALLATION OF YOUR STOVE
Before starting any installation, make sure you know :
Where do you run your gas line ;
What type of venting kit do you need (page 5) ;
Where do you run you’re your venting pipes ;
Where do you install the terminal vent in respect with installation code (page 7 and 8) ;
Clearances to combustibles (page 6) ;
Length of horizontal and vertical runs of venting pipes
Now that you have decided where and how to install your stove,
you are ready to start:
Pedestal cover
1. Slide the pedestal cover over the pedestal from the front.
2. Place the back cover on the pedestal cover and secure with
the supplied screws.