MANUAL FLUSH OPERATION
In the event of an electrical failure, the flush ball can be manually operated to clear the bowl. We recommend using
a long-neck screwdriver or 7/16-in. socket for the operation shown below. NEVER PRY OPEN THE FLUSH BALL
FROM INSIDE THE TOILET BOWL. Damage to the flush ball and bowl seals may result.
2. Locate hole on left side
of china toilet. This al-
lows access to the flush
valve motor drive arm.
3. Insert screwdriver or
7/16-in. socket through
access hole and onto hex
head.
4. Turn screwdriver or sock-
et counter-clockwise.
This will open flush ball
and allow bowl contents
to clear. After bowl is
clear, turn screwdriver or
socket clockwise to return flush ball to original position.
1. Remove PC board ac-
cess cover. Place Mode
Switch in the “Manual
Override” position. This
disconnects flush valve
motor brake from electri-
cal circuit.
NOTES:
Water will not enter the toilet bowl during manual flush
operation.
Place Mode Switch in the “Normal” position before
returning to automatic operation.
TOILET SYSTEM ELECTRICAL SPECIFICATIONS
12VDC 24VDC
Maximum standby current (amps): .080 .080
Maximum operating current (amps): 6.5 2.5
Flush motor locked rotor current (amps): 14.5 7.25
Maximum voltage 15 30
Minimum voltage: 10 20
Input power wire size 14 ga. 14 ga.
All other wires size: 18 ga. 18 ga.
Fuse size (amps) 8 4
NOTES: Standby current includes flush panel status light.
Operating current does not include vacuum pump or other sanitation system components.