DMP Electronics XR2400F Smoke Alarm User Manual


 
13
User Menu
Display Events
User Code Level: All Users.
Function: Allows you to review up to 200 past system events.
There are three applicable event types:
Zone Activity - Zone alarms, troubles, and restorals.
User Code Changes - Adding, deleting, and changing user codes.
Supervisory - Problems with the system’s hardware components.
The system’s memory can hold a maximum of 200 events for 45 days.
Any event older than 45 days is cleared automatically by the system.
Also, once the full 200 events are stored, any new event causes the
oldest event to be cleared.
Using the Display Events
1. Access the User Menu.
2. Press the COMMAND key until DISPLAY EVENTS? displays.
Press any SELECT key.
3. The display shows FRST LST PRT SRT. Select FRST (first)
to view the oldest to newest events. Select LST (last) to view the
newest to oldest events. If you select FIRST, use the COMMAND
key to scroll up through the events. If you select LAST, use the
ARROW key to scroll down through the events.
Select SRT (sort) to sort through the Display Events log and
collect information specific to a user or system event.
Select PRT (print) to print the complete Display Events log.
4. To use the Sort feature, press the SELECT key under SRT.
FRST DATE: 8/21 is displayed. Press any SELECT key and
enter a 4-digit beginning date for the sort. Press COMMAND.
5. LAST DATE: 10/17 is displayed. Press any SELECT key and
enter a 4-digit ending date for the sort. Press COMMAND.
6. USER NUMBER: - is displayed. To sort events for a particular
user, enter the user number or press COMMAND to sort for all
users. To search for a user, press any SELECT key then use the
COMMAND and ARROW keys to browse through the user
names in the system. When the user you want is displayed,
press any SELECT key then press COMMAND.
7. Next, the display shows five event types that you can include in
the sort. Press the
right
SELECT key to display YES as the event
type name is displayed. Press COMMAND.
The following are the five sort event types:
ACCESSES = door accesses granted (Not Applicable).
DOOR NUMBER = leave blank for all doors (Not Applicable).
ZONE EVENTS = zone alarms, troubles, and restorals.
USER EVENTS = adding, deleting, and changing user codes.
SUPERVISORY = system hardware problems.
8. After the last event type is displayed, again the display shows
FRST LST PRT SRT. At this point, you can view or print the
new sorted Display Events or press SRT for a new sort.