INSTALLATION AND CLEARANCES
Figure 2 shows technical information regarding
installation of your gas log set. Please make sure
all specications shown are applicable before
installation is attempted.
Note: This vented appliance must be installed
only in a solid-fuel burning or UL127 factory-
built replace with a working ue and constructed
of noncombustible material. The replace must
include a working ue and venting system with
minimum openings shown in Figure 3.
LOG SIZING REQUIREMENTS
M
Flue
Size
Size
Front
Width
Rear*
Width
18" 17" 14" 24" 20" 8"
24" 17" 14" 28" 22" 8"
*Measured at 14" depth.
FUEL INLET
MANIFOLD
NG 7" 10.5" 3.5"
LP 11" 14" 10"
Figure 2 - Technical Information Chart
Figure 3 - Sizes and Clearances
Use the correct gas type (natural or propane/LP)
for your unit. If your gas supply is not correct, do
not install heater. Call dealer where you bought
heater for proper type heater.
-
INSTALLATION
The replace chimney ue and vent must be draft-
ing properly. To check vent for proper drafting:
Light a tightly rolled newspaper on one end and
place it at the inside front edge of replace. Ob-
serve smoke and be sure vent is properly drawing
it up the chimney. If smoke spills out into the room,
extinguish ame and remove any obstruction until
proper venting is achieved.
The chimney ue damper must be xed open to
provide a minimum of 43 square inches of free
air opening during operation of this log set. A
multipurpose damper clamp is provided to x the
damper in position.