www.desatech.com
111826-02J 15
TROUBLESHOOTING
Note: All troubleshooting items are listed in order of operation.
1. Ignitor electrode not connected
to ignitor cable
2. Ignitor cable pinched or wet
3. Electronic ignitor battery is
weak
4. Broken ignitor cable
5. Bad electronic ignitor
6. Ignitor electrode positioned
wrong or broken
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas lines when in-
stalled
5. Depleted gas supply (propane/
LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
3. Replace battery
4. Replace ignitor cable
5. Replace electronic ignitor
6. Replace pilot assembly
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while in
PILOT position
4. Continue holding down
control knob. Repeat ig-
niting operation until air is
removed
5. Contact local propane/LP gas
company
6. Clean ODS/pilot (see Cleaning
and Maintenance, page 14) or
replace ODS/pilot assembly
7. Replace gas regulator
When ignitor button is pressed,
there is no spark at ODS/pilot
When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition