Design Dynamics VF-24P-MHD Gas Heater User Manual


 
www.fmiproducts.com
116986-01H16

on automatically within one min-

6. Press the buttons and at the same
time. A short acoustic signal conrms start
sequence has begun.
Further short acoustic signals (0.2 sec.,
1 Hz) indicate the ignition process until it
is completed and main gas ows. If pilot is
already lit, motor will turn on (max. ame
height) while buttons are pressed down. If
pilot does not light, see Troubleshooting,
page 21.
7. Press
to turn on main burner and
increase ame height. Press to de-
crease ame height and shut off main
burner.
8. Short tapping of either button allows
incremental change in ame height.
9. Press OFF button to switch off main gas
and pilot gas.
10. To leave pilot lit and shut off burners only,
press
to decrease ame height and
shut off main burner.
FUNCTIONS OF
REMOTE CONTROL

After the charged battery has been correctly
installed, the remote hand set is ready for
operations.
Remove the battery if the remote handset
will not be used more than one year.

The control is radio frequency operated. A
code (chosen from among 4,000 available
codes) is preset for all valves, but can be
changed if required (15 additional codes avail-
able). Change DIP switch position. (The DIP
switch is located inside the hand held control
at the top of the battery compartment.) Then
press the receiver's reset button on the bottom
of the receiver module until you hear a second
(longer) signal. When pressing the button
on the remote handset in the following 20 sec.,
the receiver learns the new code.
OPERATION
Continued
REMOTE LIGHTING
INSTRUCTIONS
WARNING:
     

-
erate heater with doors closed,
 



 
    
   
  -




-




    

Remain clear of the hearth area


1. STOP! Read the safety information,
page 15.
2. Make sure equipment shutoff valve is fully
open.
3. Turn motor knob clockwise
to the
OFF position.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information, column 1. If you
don’t smell gas, go to the next step.
5. Make sure ON/OFF switch is in "–" (ON)
position.