Design Dynamics VF-24P-MHD Gas Heater User Manual


 
www.fmiproducts.com
116986-01H12

   
    
   




CAUTION: Never connect
  

-
  


WARNING: Never connect

   
    

INSTALLATION
Continued
Fitting
Flexible Gas Hose
(if allowed by local
codes)
Figure 10 - Attaching Flexible Gas Hose
to Regulator
Installation Items Needed
Before installing heater, make sure you have
the items listed below.
external regulator (for propane/LP units
only, supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
approved exible gas line with gas connec-
tor (if allowed by local codes)
* A equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge
connection. Purchase the optional equipment
shutoff valve from your dealer. See Acces-
sories, page 25.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not re-
duce incoming gas pressure, heater regulator
damage could occur. Install external regulator
with the vent pointing down as shown in Figure
11. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new,
     -


     




Figure 11 - External Regulator With Vent
Pointing Down
Propane/LP
Supply Tank
External
Regulator
with Vent
Pointing
Down
Installation Items Needed
control cover kit (provided with heater)
approved exible gas hose (if allowed by
local codes)
sealant (resistant to propane/LP gas, not
provided)
1. Apply pipe joint sealant lightly to male
threads of gas fitting (not provided).
Connect approved exible gas hose to
inlet side of gas control (see Figure 10).
IMPORTANT: Hold gas tting with wrench
when connecting exible gas hose.
2. Position heater assembly in replace.
3. Connect to gas supply. See Connecting
to Gas Supply.