SAFETY INFORMATION
Continued
1. This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply
tank(s) outdoors (propane/LP units only).
3. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not
use any phone in your building
immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions
if you cannot reach your gas supplier, call
the re department
4. This replace shall not be installed in a bed-
room or bathroom.
5. Do not use this replace as a wood-burning
replace. Use only the logs provided with the
replace.
6. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of replace.
7. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 24.
8. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
9.
This replace needs fresh air ventilation to run
properly. This replace has an Oxygen Depletion
Sensing (ODS) safety shutoff system. The ODS
shuts down the replace if enough fresh air is not
available. See Air for Combustion and Ventila-
tion, page 5. If replace keeps shutting off, see
Troubleshooting, page 25.
10. Do not run replace
where ammable liquids or vapors are
used or stored
under dusty conditions
11. Do not use this replace to cook food or burn
paper or other objects.
12. Do not use fireplace if any part has been
exposed to or under water. Immediately call
a qualied service technician to inspect the
replace and to replace any part of the control
system and any gas control which has been
under water.
13. Do not operate replace if any log is broken.
Do not operate replace if a log is chipped
(dime-sized or larger).
14. Turn replace off and let cool before servicing.
Only a qualied service person should service
and repair replace.
15. Operating replace above elevations of 4,500
feet could cause pilot outage.
16. To prevent performance problems in
propane/LP units, do not use propane/LP
fuel tanks of less than 100 lbs. capacity
(propane/LP units only).
17. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION
Figure 1 - Log Base Assembly
Piezo
Ignitor
Optional
Remote
Control
Control
Knobs
Firebox
Hood
Firebox
Support
Log Set (VYGF shown)
Remote Selector
Switch (Optional)
Top Outer
Casing
Blower Assembly
(Optional)
Screen
Assembly
Figure 2 - Fireplace
Louver