Desa VYGF33NRC Indoor Fireplace User Manual


 
www.desatech.com
113109-01C22
OPERATING FIREPLACE
Continued


The hand-held remote can be operated using
either the manual mode (MANU) or thermo-
static mode (AUTO) (see Figure 43). To select
Fahrenheit/Centigrade mode display, carefully
press the ˚C/˚F mode button with the end of a
paper clip or similar blunt object.
Manual Mode
1.
Press the POWER and LOCK buttons togeth-
er to turn on the hand-held remote control.
2. Press the MANU button to turn on the
replace.
3. Press the POWER and LOCK buttons
together to turn off the replace.

1.
Press the POWER and LOCK buttons togeth-
er to turn on the hand-held remote control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by press-
ing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons
together to turn off the replace
Note: Do not leave the hand-held remote in the
AUTO mode close to the replace. The radiant
heat from the replace will turn off the replace.
Ideally, place the hand-held remote in the center
of the room facing towards the replace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the replace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature exceeds
82 degrees Fahrenheit (28 degrees Centi-
grade), the hand-held remote control will
perform a safety override and shut the
replace off. This feature is not available
in the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the replace after 8 minutes.

This feature allows the user to lock/unlock
the keypad on the hand-held remote in the
MANU or AUTO mode to prevent inadvertent
operation (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
OPTIONAL BLOWER
OPERATION
Locate the blower switch by opening lower
louver on replace. Blower switch is located at
lower right inside louver door.
The GA3700T Series thermostat-controlled
blower has a variable speed control with an
ON/OFF switch. The blower will start when the
thermostat senses a sufcient increase in rebox
temperature. The GA3700 series variable speed
blower also has an ON/OFF switch built into the
variable speed control.
Note for GA3700T Series Only: If you are us-
ing GA3700T blower, your replace and blower
will not turn on and off at the same time. The
replace may run for several minutes before the
blower turns on. After the heater modulates to
the pilot position, the blower will continue to
run. The blower will shut off after the rebox
temperature decreases.
Note: It is safe to operate replace with blower
turned off. However, the blower helps distribute
heated air from the replace.
Follow installation instructions included with
the blower accessory.
Figure 43 - Thermostat Hand-Held
Remote Control Unit (HRC200)
LOCK
MANU AUTO
ºC/ºF
TEMP
POWER
ROOM
TEMP
SET
TEMP
AUTO
Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting
Selects
AUTO
Mode
°C/°F Mode
Button
Locks
System to
Prevent
Accidental
Ignition
Turns
Burners
On or
Off
Increases
or Decreases Room
Temperature in
AUTO Mode
Digital Display Shows
Temperature and Settings