Desa VYGF33NRC Indoor Fireplace User Manual


 
www.desatech.com
113109-01C10
INSTALLATION
Continued
CONVENTIONAL FIREPLACE
INSTALLATION
Conventional installation of this replace involves
installing replace along with the corner, face or
cabinet mantel with hearth base accessories against
a wall in your home. Follow the instructions below
to install the replace in this manner.
Note: The instructions in this section show instal-
lation using the cabinet mantel and hearth base
accessories. The hearth base accessory shown
is optional for this installation. You can install
replace and cabinet mantel directly on the oor.
The corner mantel accessory (VYGF models only)
can only be paired with the corner hearth base. If
mounting replace and cabinet or corner mantel
to the oor, an optional G3005 Series Slim Base
kit may be installed.
1. Assemble cabinet mantel, hearth base and
trim accessories. Assembly instructions are
included with each accessory.
2. When installing blower, install a properly
grounded, 120 volt three-prong electrical out-
let at replace location if an outlet is not there.
If possible, locate outlet so cabinet mantel will
cover it when installed (see Figure 9).
3.
Install gas piping to replace location. This in-
stallation includes an approved exible gas line
(if allowed by local codes) after the equipment
shutoff valve. The exible gas line must be the
last item installed on the gas piping. See Install-
ing Gas Piping to Fireplace Location, page 13.
4. Place hearth base accessory against wall at
installation location. Cut an access hole in
hearth top to run exible gas line to replace
(see Figure 9). Make sure to locate access hole
so cabinet mantel will cover it when installed.
Note: You can secure base to oor using wood
screws. Countersink screw heads and putty over.
5. Route exible gas line through access hole in
hearth base.
6. Center cabinet mantel on hearth base (see Figure
10). Make sure mantel is ush against wall.
7. Break off nailing anges (see Figure 11) with
hammer or pliers.
8. Place cardboard or other protective material
on top of hearth base. Carefully set replace
on protective material, with back of replace
inside mantel opening.
9. Attach exible gas line from replace gas
regulator to gas supply. See Connecting
Fireplace to Gas Supply, page 14.
Figure 9 - Placing Hearth Base
Accessory Against Wall
Electrical
Outlet
Hearth
Base
Rigid
Gas
Line
Gas
Line
Access
Hole
Figure 10 - Installing Cabinet Mantel
Cabinet
Mantel
Figure 11 - Location of Nailing Flanges
Nailing
Flanges
Figure 12 - Inserting Fireplace Into
Cabinet Mantel