Desa VTN25R, VTP22R Water Heater User Manual


 
www.desatech.com
113261-01A
14
F
TEMPSET
ON
ROOM
OFF
MODE
SET
OPERATING HEATER
Continued
HAND-HELD REMOTE
CONTROL OPERATION
1. Slide selector switch on remote receiver to
the REMOTE position.
2. Slightly pull and turn auxiliary knob so the
AUX is to the left and right and ON is to the
top and bottom positions.
3. Light the pilot. Follow steps 1 through 6
under Lighting Instructions, page 13.
DISPLAY
The LCD display on the remote control indi
-
cates current room temperature in Fahrenheit
or Celsius. The small flame indicates burner/
valve in operation. ROOM indicates remote
is in thermo operation. TEMP appears during
manual operation. SET appears during the
time of setting the desired temperature in the
thermo operation.
Turns
heater
ON
Turns
heater
OFF
Changes heater
from Manual
Mode to
Thermo Mode
Sets
temperature in
Thermo Mode
Figure 19 - Hand-Held Remote Control Unit
SETTING FAHRENHEIT AND CELSIUS SCALE
The factory setting for temperature is Fahr-
enheit. To change this setting to Celsius, press
the ON and OFF buttons on remote at the same
time. Follow the same procedure to change from
Celsius back to Fahrenheit.
MANUAL FUNCTION
On Operation
When the ON button is pressed the appliance
flame will come on. The LCD screen will show
ON for three seconds, then default to room
temperature and the word TEMP and flame
icon will show.
Off Operation
When the OFF button is pressed the appliance
flame will shut off. The LCD screen will show
OF for three seconds, then default to room tem
-
perature and the word TEMP will show.
9. With the auxiliary knob in the AUX posi
-
tion, push the ON button on the remote
control. To adjust the temperature with the
remote control, follow the instructions on
page 15. When the temperature surround
-
ing the remote control drops below the set
temperature, the burner should light. The
remote receiver behind the unit must be in
the REMOTE position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Press in and turn pilot knob clockwise
to the OFF position.
2. Unplug any electrical power to the appli
-
ance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
If auxiliary knob is in AUX position, push OFF
button on remote control.
If auxiliary knob is in ON position, turn pilot
knob clockwise to the PILOT position.
THERMOSTAT
OPERATION
The thermostat used on this heater senses the
room temperature at the location of the hand-
held remote control. At times the room may
exceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
room temperature drops below the set tempera-
ture. All plaques will turn off and on.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Lighting
Instructions, page 13.
2. With pilot knob pressed in, strike match.
Hold match to pilot until pilot lights.
3. Keep pilot knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
pilot knob. Continue with step 8 under
Lighting Instructions, above.