Desa VTN25R, VTP22R Water Heater User Manual


 
www.desatech.com
13113261-01A
OPERATING HEATER
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighborʼs phone. Follow the gas
supplierʼs instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, donʼt
try to repair it, call a qualified service tech
-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully
open.
3. Turn pilot knob clockwise
to the OFF
position.
4. Wait five minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety
information above. If you donʼt smell gas,
go to the next step.
5. Press in pilot knob and turn counterclock
-
wise to the PILOT position. Keep
pilot knob pressed in for five (5) seconds
(see Figure 17).
Note: You may be running this heater for
the first time after hooking up to gas supply.
If so, the pilot knob may need to be pressed
in for 30 seconds or more. This will allow
air to bleed from the gas system.
• If pilot knob does not pop up when re
-
leased, contact a qualified service person
or gas supplier for repairs.
6. With pilot knob pressed in, push in ignitor
button. This will light pilot. The pilot is
located at the bottom of plaque burners. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 17. Also contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with a match. To light pilot with a match,
see Manual Lighting Procedure, page 14.
7. Keep pilot knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
pilot knob.
• If pilot knob does not pop up when re
-
leased, contact a qualified service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7.
8.
With the auxiliary knob in the ON posi-
tion, turn pilot knob counterclockwise
to start the heater. The main burner
should light.
Figure 18 - Pilot
Ignitor Electrode
Pilot
Burner
Thermocouple
A
U
X
O
N
A
U
X
O
N
O
F
F
P
I
L
O
T
O
N
Figure 17 - Pilot Knob In The ON Position
Electronic Ignitor
Button
Auxiliary
Knob
Pilot
Knob