Desa (V)KC42P SERIES Indoor Fireplace User Manual


 
www.desatech.com
116239-01D 7
A
B
E
F
G
H
D
C
Nailing Tabs
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
40
1
/8"
48
1
/4"
23" Horizontal Vent
26
1
/2" Vertical Vent
C
B
A
D
E
F
G
Top of Louver
Opening
3
2
1
4
5
6
7
Wall
Figure 5 - Framing Clearances for Corner
Installation
Ref. Mantel Depth Ref.
Mantel from
Top of Louver
Opening
1 14" (356 mm) A 16" (406 mm)
2 12" (305 mm) B 14" (356 mm)
3 10" (254 mm) C 12" (305 mm)
4 8" (203 mm) D 10" (254 mm)
5 6" (152 mm) E 8" (203 mm)
6 4" (101 mm) F 6" (152 mm)
7 2" (51 mm) G 4" (101 mm)
Figure 6 - Clearances for Combustible
Mantels
48"
48
1
/
4
"
41
5
/
8
"
21
5
/
8
"
58
1
/2"
16
3
/
4
"
81
1
/
2
"
13
1
/
2
"
PRE-INSTALLATION
PREPARATION
Continued
Nailing
Tabs
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation. All
minimum clearances must be met.
For available accessories for this replace, see
Accessories on page 42. If you are using a sepa-
rate combustible mantel piece, refer to Figure 6
for proper installation height. You can install
noncombustible mantels at any height above the
replace.
Note: Noncombustible mantels may discolor!