www.desatech.com
116239-01D 17
VENTING INSTALLATION
INSTRUCTIONS
Continued
Note: Install
restrictor into
inner collar of
replace as
shown.
Vertical (V
1
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
Note: Vertical (V
1
) + Vertical (V
2
) = 40' max.
Figure 23 - Vertical Venting
Conguration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
45° Elbow
V = 40' max.
Figure 24 - Vertical Venting
Conguration With No Horizontal Run
(Vertical Round High Wind Termination
Shown)
Note: Install
restrictor into
inner collar of
replace as
shown.
45° Elbow
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent replace has been tested and
approved for elevations from 0-2000 feet (USA) and
elevations from 0-4500 feet (Canada).
Fireplaces for High Altitude (models ending in
-HA) are for installation above 4000 feet only.
These replaces are equipped with parts specic
for higher altitudes. IMPORTANT: These replac-
es can NOT be converted to Propane/LP gas.
When installing a non-high altitude replace at an
elevation above 2000 feet (in the USA), you may
need to decrease the input rating by changing the
existing burner orice to a smaller size. Reduce
input 4% for each 1000 feet above sea level. Check
with your local gas company for proper orice
size identication.
When installing this fireplace at an elevation
above 4500 feet (in Canada), check with local
authorities.