Desa VI33NRB Indoor Fireplace User Manual


 
www.desatech.com
113195-01B 23
BURNER FLAME PATTERN
Figure 39 shows a correct burner flame pattern.
Figure 40 shows an incorrect burner flame pattern.
If burner flame pattern is incorrect,
turn heater off (see To Turn Off Gas to Appli
-
ance, page 20)
see Troubleshooting
, page 25
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in
the fitting at the burner entrance. These holes may
become blocked with dust or lint. Periodically
inspect these holes for any blockage and clean if
needed. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with
the heater running. All slotted burner flame holes
should be open with yellow flame present. All
round burner flame holes should be open with a
small blue flame present. Some burner flame holes
may become blocked by debris or rust, with no
flame present. If so, turn off heater and let cool.
Remove blockage, blocked burner flame holes
will create soot.
Figure 39 - Correct Flame Pattern with
Control Knob Set to High Flame.
Figure 40 - Incorrect Flame Pattern with
Control Knob Set to High Flame
INSPECTING BURNERS
Continued
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualified service person. Heater
may need more frequent clean-
ing due to excessive lint from
carpeting, pet hair, bedding
material, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount
of air to mix with the gas. This provides a clean
burning flame. Keep these holes clear of dust, dirt,
lint and pet hair. Clean these air inlet holes prior to
each heating season. Blocked air holes will create
soot. We recommend that you clean the unit every
three months during operation and have heater
inspected yearly by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI. Your local
computer store, hardware store or home center
may carry compressed air in a can. You can use a
vacuum cleaner in the blow position. If using com
-
pressed air in a can, please follow the directions on
the can. If you donʼt follow directions on the can,
you could damage the pilot assembly.