Desa VGC30NR/PR Electric Heater User Manual


 
www.desatech.com
119162-01C 5
PRODUCT
IDENTIFICATION
Figure 1 - Product Identication
AUTO/
OFF/ON
Switch
Chassis
OPTIONAL REMOTE
CONTROL ACCESSORIES
There are four optional remote controls that
can be purchased separately for Remote-Ready
Models Only:
wall switch hand-held ON/OFF remote
wall thermostat hand-held thermostat remote
See Accessories, page 33.
The wall thermostat or hand-held thermostat may not
be used where vented decorative listing is required.
UNPACkING
CAUTION: Do not remove the
     -

   

1. Remove logs and heater base assembly from
carton. Note: Do not pick up heater base as-
sembly by burners. This could damage heater.
Always handle base assembly by grate.
2. Remove all protective packaging applied to
logs and heater for shipment.
3. Check all items for any shipping damage. If
damaged, promptly inform dealer where you
bought heater.
PRODUCT FEATURES
OpERATION
This heater is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a
chimney. Heat is generated by both realistic ames
and glowing coals. This heater is designed for vent-
free operation with ue damper closed. It has been
tested and approved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in some ar-
eas prohibit the use of vent-free heaters. This heater
may also be operated as a vented decorative (ANSI
Z21.60) product by opening the ue damper.

This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
ELECTRONIC IGNITION SYSTEM
This heater has an electronic ignitor to light heater
fuel supply.
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installa-
tion must be made by a licensed plumb-
er or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-
red supplemental room heaters shall provide
to each purchaser a copy of 527 CMR 30 upon
sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
Glowing
Embers
Electronic
Ignitor
Control
Knob
Remote
Control
(Optional)
Flame
Adjustment
Knob