SPECIFICATIONS
REMOTE-READY MODELS

Rating (Variable): 24,000/30,000 Btu/Hr
Type Gas: Propane/LP
Ignition: Electronic
Manifold Pressure: 7.9" W.C.
Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.

Rating (Variable): 21,000/30,000 Btu/Hr
Type Gas: Natural
Ignition: Electronic
Manifold Pressure: 3.4" W.C.
Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.

Rating (Variable): 25,000/36,000 Btu/Hr
Type Gas: Propane/LP
Ignition: Electronic
Manifold Pressure: 7.9" W.C.
Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.

Rating (Variable): 25,000/36,000 Btu/Hr
Type Gas: Natural
Ignition: Electronic
Manifold Pressure: 3.4" W.C.
Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment

Rating (Variable): 25,000/36,000 Btu/Hr
Type Gas: Propane/LP
Ignition: Electronic
Manifold Pressure: 7.9" W.C.
Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.

Rating (Variable): 25,000/36,000 Btu/Hr
Type Gas: Natural
Ignition: Electronic
Manifold Pressure: 3.4" W.C.
Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
SERVICE HINTS
When Gas pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specied heat
propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-
tact your local propane/LP or natural gas supplier.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ techni-
cal services web site at .
REPLACEMENT PARTS
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
pARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating Products’ Technical Service
Department at 1-866-672-6040.
When calling DESA Heating Products, have
ready
your name
your address
model and serial numbers of your heater
how heater was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the part to the
factory.
pARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA Heating Products at 1-866-672-6040 for
referral information.
When calling DESA Heating Products, have
ready
model number of your heater
the replacement part number