6. Press in and turn control knob counterclockwise
to the PILOT position. Press in control
knob for ve (5) seconds (see Figure 29).
Note: You may be running this heater for the
rst time after hooking up to gas supply. If
so, the control knob may need to be pressed
in for 30 seconds or more. This will allow air
to bleed from the gas system.
7. With control knob pressed in, press and release
ignitor button on left side of log set. This will
light pilot. The pilot is attached to the front
of U-shaped burner. If needed, keep pressing
ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a quali-
ed service person or gas supplier for repairs.
Until repairs are made, light pilot with match.
To light pilot with match, see Manual Lighting
Procedure, page 21.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when re-
leased, contact a qualied service person or
gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise to the ON position. If
using a hand-held remote control accessory,
go to Optional Hand-Held Remote Operation
on page 21.
OPERATING HEATER
Continued
AUTO
OFF
ON
Figure 29 - Control Knob, Ignitor Button
and AUTO/OFF/ON Switch
Selector Switch
Control Knob in
OFF Position
Flame
Adjustment
Knob
Ignitor
LIGHTING
INSTRUCTIONS
WARNING:
     

-
erate heater with doors closed,
 













Note: Home owners generally prefer to operate
their heater with the chimney damper closed.
This will put all the heat into the room. However,
there may be times you will desire the full ames
of the HI heat setting but will nd the heat output
excessive. You can open the chimney damper (if
you have one) fully or partially to release some
of the heat.
 
      

1.
STOP! Read the safety information on page 19.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch to OFF position.
4. Press in and turn control knob clockwise
to the OFF position (see Figure 29).
5. Wait ve (5) minutes to clear out any gas. Then
smell for gas, including near the oor. If you
smell gas, STOP! Follow “B” in the safety
information, page 19. If you don’t smell gas,
go to the next step.