Desa VGC24NR/PR Electric Heater User Manual


 
www.desatech.com
119162-01C 9


  
    
18" 19" 14" 28" 20"
24" 19" 14" 32" 22"
30" 19" 14" 40" 30"
*Measured at 14" depth
CAUTION: This heater cre-
    
currents move heat to wall sur-
 
heater next to vinyl or cloth wall
   


-

the air exist, may discolor walls

IMPORTANT: Vent-free heaters add moisture to
the air. Although this is benecial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation, page 6.
CHECK GAS TYpE
Use the correct type of gas (natural or propane/LP).
If your gas supply is not the correct gas type, do
not install heater. Call dealer where you bought
heater for proper type heater.
   
-
 

INSTALLATION AND CLEARANCES

WARNING: Maintain the
   



MINIMUM FIREpLACE CLEARANCE TO

: 18", 24", 30", Side Wall: 16"
: 42", Floor: 5"
INSTALLATION
Continued
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured replace or listed vent-free
rebox.
Minimum Clearances For Side


A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This combus-
tible material must be 4" from the side of the
replace cabinet (see Figure 4).
Note: When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer’s instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the replace opening
to the ceiling should not be less than 42".
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example