A SERVICE OF

logo

www.desatech.com
119162-01B20
6. Press in and turn control knob counter-
clockwise to the PILOT position.
Press in control knob for ve (5) seconds
(see Figure 29).
Note: You may be running this heater for
the rst time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button on left side of log set.
This will light pilot. The pilot is attached
to the front of U-shaped burner. If needed,
keep pressing ignitor button until pilot
lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualied service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8, page 20 and above.
9. Slightly push in and turn control knob coun-
terclockwise to the ON position. If
using a hand-held remote control accessory,
go to Optional Hand-Held Remote Operation
on page 21.
OPERATING HEATER
Continued
AUTO
OFF
ON
Figure 29 - Control Knob, Ignitor Button
and AUTO/OFF/ON Switch
Selector Switch
Control
Knob in OFF
Position
Flame
Adjustment
Knob
Ignitor
LIGHTING
INSTRUCTIONS
WARNING:
     

-
erate heater with doors closed,
 













Note: Home owners generally prefer to op-
erate their heater with the chimney damper
closed. This will put all the heat into the room.
However, there may be times you will desire
the full ames of the HI heat setting but will
nd the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
 
      

1. STOP! Read the safety information on
page 19.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch to OFF position.
4. Press in and turn control knob clockwise
to the OFF position (see Figure 29).
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the
safety information, page 19. If you don’t
smell gas, go to the next step.