15
103280
INSTALLING
Continued
Mantel Clearances for Built-In Installation
If placing mantel above built-in fireplace, you must meet minimum clearance
between mantel shelf and top of fireplace opening.
If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.
Distances to
Underside of
Mantel
Underside of
Mantel Shelf
20" 24
1
/2
" 27
1
/2
" 30"
All minimum
distances are
in inches
Top of
Fireplace
Opening
2
1
/2
"
6"
8"
10"
Figure 15 - Minimum Mantel Clearances for Built-In Installation
Mantel Shelf
INSTALLING GAS PIPING TO FIREPLACE LOCATION
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to LP/propane gas)
• manual shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with
gas connector
(if allowed by
local codes) (not provided)
NOTICE
A qualified service person must connect fireplace to gas supply.
Follow all local codes.
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual
shutoff valve from your dealer. See Accessories, page 34.
WARNING ICON G001
CAUTION
Never connect heater directly to the propane supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.
Continued