25
103280
Figure 31 - Pilot
6. Continue pressing control knob in. Press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure, below.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
Thermocouple
Ignitor Electrode
Pilot Burner
OPERATING
FIREPLACE
Manually-Controlled
Models
Continued
8. Slightly depress and turn control knob counterclockwise
C-clockwise
to the HIGH
position. Both burners should light. Set control knob to either HIGH or LOW.
TO TURN OFF GAS TO APPLIANCE
WARNING ICON G001
WARNING
Do not operate heater between locked positions.
WARNING ICON G001
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
VARIABLE CONTROL OPERATION
The variable control valve can be set to any heat setting and flame height desired, by
simply turning the control knob until that setting is attained. Even the lowest setting
provides realistic flames and glowing embers from two burners. Selecting higher
settings produces greater heat output. This results in increased heating comfort.
Shutting Off Fireplace
1. Turn control knob clockwise
Clockwise
to the HIGH position.
2. Slightly depress control knob and turn clockwise
Clockwise
to the PILOT position.
3. Slightly depress control knob and turn clockwise
Clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise
Clockwise
to the HIGH position.
2. Press in and turn clockwise
Clockwise
to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 24.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob. Now follow step 8, above.
Continued