INSTALLING
NOTICE
A qualified service person must install fireplace. Fol-
low all local codes.
WARNING ICON G 001
WARNING
Never install the fireplace
in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-
mable objects are less than 36 inches from the
front, top, or sides of the fireplace
• in high traffic areas
• in windy or drafty areas
Continued
IMPORTANT:
Vent-free heaters add moisture to the air. Although this is beneficial,
installing fireplace in rooms without enough ventilation air may cause mildew to
form from too much moisture. See Air for Combustion and Ventilation, pages 6
through 8.
IMPORTANT:
Make sure the fireplace is level. If fireplace is not level, log set will
not work properly.
WARNING ICON G 001
CAUTION
This fireplace creates warm air currents. These cur-
rents move heat to wall surfaces next to fireplace.
Installing fireplace next to vinyl or cloth wall coverings
or operating fireplace where impurities in the air (such
as tobacco smoke) exist, may discolor walls.
CHECK GAS TYPE
Use only propane gas. If your gas supply is not propane gas, do not install fireplace.
Call dealer where you bought fireplace for proper type fireplace.