Desa UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE Indoor Fireplace User Manual


 
26
101969
CLEANING
AND
MAINTENANCE
WARNING ICON G 001
WARNING
Turn off fireplace and let cool before cleaning.
POSSIBLE
CAUSE
1. Ignitor electrode not con-
nected to ignitor cable
2. Piezo ignitor nut is loose
3. Ignitor cable pinched or
wet
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode posi-
tioned wrong
REMEDY
1. Reconnect ignitor cable
2. Tighten nut holding
piezo ignitor to base
panel of log set. Nut is
located behind base
panel.
3. Free ignitor cable if
pinched by any metal or
tubing. Keep ignitor
cable dry
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace ignitor
7. Replace ignitor
OBSERVED
PROBLEM
When ignitor button
is pressed, there is no
spark at ODS/pilot
WARNING ICON G 001
CAUTION
You must keep control areas, burners, and circulating
air passageways of fireplace clean. Inspect these
areas of fireplace before each use. Have fireplace
inspected yearly by a qualified service person. Fire-
place may need more frequent cleaning due to exces-
sive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNERS
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to
properly replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
TROUBLE-
SHOOTING
Note:
All troubleshooting
items are listed in order of
operation.
WARNING ICON G 001
WARNING
Turn off fireplace and let cool before servicing. Only
a qualified service person should service and repair
fireplace.
WARNING ICON G 001
CAUTION
Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.