www.desatech.com
113109-01G 15
INSTALLATION
Continued
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Remove replace screen. Remove two
screws that hold replace screen in place
for shipping. These screws are located
near top of screen. Discard screws. Lift
replace screen up and pull out to re-
move.
2. Remove screws that attach log base
assembly to replace. Carefully lift up
log base assembly and remove from
replace. See Figure 19.
Note: If adding the G8005 series brick liner
accessory, install it now. Follow instructions
in G8005 accessory kit.
3. Route gas line (provided by installer)
from equipment shutoff valve to replace.
Route exible gas supply line through one
of the access holes.
Figure 19 - Removing Log Base
Assembly From Fireplace
-
4. Attach the exible gas line to gas supply.
Check tightness of exible gas line at-
tached to gas regulator of replace. See
Figure 20.
5. Check all gas connections for leaks. See
Checking Gas Connections.
6. Replace log base assembly back into
replace. Feed exible gas line into re-
place base area while replacing log base
assembly. Make sure the entire exible
gas line is in replace base area. Reat-
tach log base assembly to replace with
screws removed in step 2.
Figure 20 - Attaching Flexible Gas Lines
Together
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace Gas
Regulator
Equipment Shutoff Valve
Provided by Installer
To External
Regulator
Natural Gas
To Gas Meter
and connections, internal and
external to unit, for leaks after
WARNING: Never use an
-