INSTALLATION
Continued
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
5/16" hex socket wrench or nut-driver
Phillips screwdriver
sealant (resistant to propane/LP gas, not
provided)
1. Remove replace screen. Remove two
screws that hold replace screen in place
for shipping. These screws are located
near top of screen. Discard screws. Lift
replace screen up and pull out to re-
move.
2. Remove screws that attach log base
assembly to replace. Carefully lift up
log base assembly and remove from
replace. See Figure 19.
Note: If adding the G8005 series brick liner
accessory, install it now. Follow instructions
in G8005 accessory kit.
    
    


3. Route gas line (provided by installer)
from equipment shutoff valve to replace.
Route exible gas supply line through one
of the access holes.
Figure 19 - Removing Log Base
Assembly From Fireplace
   
    



-


4. Attach the exible gas line to gas supply.
Check tightness of exible gas line at-
tached to gas regulator of replace. See
Figure 20.
5. Check all gas connections for leaks. See
Checking Gas Connections.
6. Replace log base assembly back into
replace. Feed exible gas line into re-
place base area while replacing log base
assembly. Make sure the entire exible
gas line is in replace base area. Reat-
tach log base assembly to replace with
screws removed in step 2.
Figure 20 - Attaching Flexible Gas Lines
Together
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace Gas
Regulator
Equipment Shutoff Valve
Provided by Installer

To External
Regulator
Natural Gas
To Gas Meter


and connections, internal and
external to unit, for leaks after


WARNING: Never use an

-


