www.desatech.com
113109-01G10
INSTALLATION
Continued
Figure 9 - Placing Hearth Base
Accessory Against Wall
Electrical
Outlet
Hearth
Base
Rigid
Gas
Line
Gas
Line
Access
Hole
Figure 8 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
Example
*
INSTALLATION CLEARANCES
WARNING: Maintain the
Carefully follow the instructions below. This
will ensure safe installation.
A. Clearances from the side of the replace
cabinet to any combustible material and
wall should follow diagram in Figure 8.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This com-
bustible material must be 4" from the side
of the replace opening (see Figure 8).
B.
Clearances from the top of the replace
opening to the ceiling should not be less
than 42".
CONVENTIONAL FIREPLACE
INSTALLATION
Conventional installation of this fireplace
involves installing replace along with the
corner, face or cabinet mantel with hearth
base accessories against a wall in your home.
Follow the instructions below to install the
replace in this manner.
1. Assemble cabinet mantel, hearth base
and trim accessories. Assembly instruc-
tions are included with each accessory.
2. When installing blower, install a properly
grounded, 120 volt three-prong electrical
outlet at replace location if an outlet is not
there. If possible, locate outlet so cabinet
mantel will cover it when installed (see
Figure 9).
Figure 7 - Attaching Perimeter Trim to
Fireplace
Trim
Hanging
Screws
Assembled
Trim
Hanging
Notches
on Trim
7. Repeat steps 1 through 6, page 9, for
other side.
8. Tighten trim hanging screws (#10 x 6.25
shoulder) into holes in cabinets. Place
the assembled trim onto replace cabinet.
Align hanging notches on trim with hang-
ing screws on side of replace (see Figure
7). Push trim rmly into place, sliding
hanging notches over hanging screws.
MINIMUM CLEARANCE TO