www.desatech.com
117437-01D 25
LOGS
Installing Logs and Glowing Embers
carbon buildup on logs.
• Replace log(s) if broken. See Replacement
Parts, page 31.
• Replace ember material periodically as
needed. See Replacement Parts
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather corrosion (rust
CLEANING AND MAINTENANCE
Continued
holes). Have these items replaced im-
into vent. Remove any foreign material.
3. Check for evidence of excessive con-
densation. Continuous condensation can
and can be caused by having excessive
portions of the system being exposed to
cold weather.
-
loosened. Check mechanical supports
such as wall straps for rigidity.
SPECIFICATIONS
(V)CB36N
• Gas Type: Natural
(0.082")
• Ignition: Millivolt
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36P
• Gas Type: Propane/LP
(0.052")
• Ignition: Millivolt
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
(V)CB36NE
• Gas Type: Natural
(0.082")
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36PE
• Gas Type: Propane/LP
(0.052")
• Ignition: Electronic
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
ALL MODELS
• Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
-
ply may be low
You may feel your gas pressure is too low. If
gas supplier.
TECHNICAL SERVICES
You may have further questions about installa-
-
When calling please have your model and
serial numbers of your heater ready.
site at www.desatech.com.