Louisville Tin and Stove HEDV404 Furnace User Manual


 
HEVK-5 5' VENT EXHAUST KIT
INSTALLATION INSTRUCTIONS
WARNING: Use only Louisville Tin & Stove Company factory supplied parts and kits. Failure to do so could result in
loss of life, personal injury, property damage, or unsatis*actory performance.
CONTENTS OF KIT
1only P/N 72532 21_x3',' Steel Coupling 1only P/N 41520 Center Bracket
1only P/N 72575 2,,x5, Black Flocked Tube 8 only P/N 72593 2" Hose Clamps
1only P/N 72612 2 x6 Black Flex Tubing 1only P/N 72578 2"x3" Black S_licone
2 only P/N 41515 Support Brackets _ Wrapped Coupling
STEP 1 - LOCATE VENT OPENING
a) Select location on outside wall that vent wilt exit through.
b)
Check outside for p,roper clearances around vent cap. See installation instructions.
" Mark and cut 3-1/2 hole through both inside and outside walls, being sure to maintain level across both openings.
_ Measure wall thickness. Mark and cut offboth intake and exhaust pipes to 1/2 beyond outside wall.
_)TEP Secure collection box to wall. Wall anchors, not provided, may be required.
2 - INSTALL HEATER
} Select location on wall where heater will be installed.
Using wall template supplied with heater, mark location for trim kit wall brackets.
Attach brackets to wall (wall anchors, not provided may be required) and back of heater. Using screws provided on
back of heater.
d) Slide heater into position and secure brackets togehter. This should position back of heater 5" offwall.
e) Select direction vent will exit trim kit, left, right, or straight up.
t) Before installing trim kit remove kalockout on this side.
STEP 3 - INSTALL VENT
al Relnoveanddiscard,P/N72611 2"x24" black flex tubing tioln air inlet. (Save hgse clamp).
Attach P/N 72612 ,,2x,6 black flex tubing to air inlet. S_cure with P/N 72593 2 hose clamp.
cl
Slide P/N 72575 2 x5 flocked tube through trim kit opening (knockout) and attach to P/N 7-2610orange silicone
90 elbo,a supplied ,aith heater. Secure ,alth 2 hose clamp7
d) Attach P!N 41515 support brackets to wall. Wall anchors, not provided, may be required. Postion sup_grt brackets
within 8 from side of trim kit and end of pipe. Secure flex tubing and flocked tube to brackets using 2' hose
clamps.
e) Attach P/N 41520 center bracket 2-1/2 from pipe end and insert flex tube through bracket. This will prevent the
flex tube tioln touching the black flocked exhaust robe.
t) Connect flex air intake_mbe and flocked exhaust tube to collection box.
g) Complete gas connection and attach trim kit to brackets.
h) Follow ligl_ting instructions.
SPECIAL NOTES
a) You may use up to three HEVK-5 Kits for a total of 15' vent extension with two additional elbows. DONOT
EXTEND VENT BEYOND 15 OR USE MORE THAN THREE TOTAL ELBOWS (one elbow is attached to
heater outlet).
bl To connect two vent kits together use P/N 72532 2"x3" steel coupling. Secure with 2" hose clamps.
If you are using one, two, or three kits, after installation is complete you will discard 2 P/N 72593hose clamps and
one P/N 72532_steel co%ling. _ .
d_ If you need to make a 90 • otl_et you will need to order P/N HEEL-1 90' Elbow Kit. Two ofl;ets require two ldts.
If complete vent extension is horizontal, pipes may be sloped down slightly to allow any condensate to
drain through the exhaust pipe to the outside. DO NOT ALLOW TO DRAIN ONTO WALKWAY. If any part of
vent extension is vertical or local codes do not allow draining of condensate to outside you must add P/N HECK-1
Condensate Kit.
t) For cosmetic purposes, the addition of the HEVK-5 Kit can be enclosed by adding a HEVE-5 Vent Enclosure Kit.
To completely enclose the HEVK-5 Kit one HEVE-5 will be needed for each HEVK-5 used.
PiN 72612
2"x6" Black
Flex Tubing
72532
e only if connecting
flex tubing of 2 or
_2_3 _ lnore ktis
P 'BNlaTck57_i 151_/
Support /
Wrapped Coupling Brackets (2) _'J" ,
C2Nr '4B15_Oet-_ Z/j
PiN 72575 2"x5'
Black
PiN 72593
2" Hose Clamps
Page 14