Louisville Tin and Stove 90N75A Furnace User Manual


 
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
SAFETY RULES - Continued
FOLLOW ALL APPLICABLE CODES AND ORDINANCES. IF THERE ARE NONE, FOLLOW THE
INSTALLATION STANDARDS, LATEST EDITION OF NFPA54/ANSI.Z223.1. A COPY MAY BE OBTAINED
FROM THE AMERICAN GAS ASSOCIATION, 1515 WILSON BLVD., ARLINGTON, VA. 22209, OR THE
NATIONAL FIRE PROTECTION ASSOCIATION, BATTERYMARCH PARK, QuiNcY, MA. 02269.
DO NOT INSTALL THIS FLOOR FURNACE IN ARECREATIONAL VEHICLE, TRAILER OR MOBILE HOME.
DO NOT OPERATE THIS FLOOR FURNACE UNLESS IT IS CONNECTED TO A PROPERLY INSTALLED AND
MAINTAINED VENT SYSTEM. DO NOT EXHAUST FLUE GASES UNDER THE FLOOR FOR ANY REASON.
BE SURE THIS FLOOR FURNACE IS EQUIPPED FOR THE TYPE GAS YOU INTEND TO USE.
LOCATE THE THERMOSTAT IN A ROOM OR SPACE THAT CANNOT BE SEPARATED BY A DOOR OR
OTHER MEANS FROM THE ROOM OR SPACE IN WTIICH THE FLOOR FLIRNACE GRILL ISINSTALLED.
NEVER USE A MATCH, CANDLE, FLAME OR OTHER SOLIRCE OF IGNITION TO CHECK FOR GAS LEAKS.
USE ONLY SOAPY WATEROR LIQUID DETERGENT.
ADEQUATE AIR FOR COMBUSTION AND VENTING MUST BE PROVIDED.
IF IT IS SUSPECTED THAT RISING WATER OR SEEPAGE MAY ENTER THE FLOOR FURNACE, TURN OFF
THE GAS IMMEDIATELY DO NOT USE THIS FLOOR FURNACE IF ANY PART HAS BEEN tENDER WATER.
IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FLOOR FURNACE AND TO
REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER
WATER.
HAVEYOLIR FLOOR FURNACE AND VENT SYSTEM INSPECTED ATLEAST ANNUALLY BY A QUALIFIED
SERVICE TECHNICIAN.
THE GRILL BECOMES HOT WHEN THE FLOOR FLJRNACEISIN OPERATION. CHILDRENMEYSTBE CLOSELY
SUPERVISED WHEN IN THE PRESENCE OF ANY HEATINGAPPLIANCE. CONTACT WITH BARE SKIN MAY
RESULTIN SEVERE BURNS. KEEP CHILDREN OFF THE GRILL.
BEFORE CLEANING OR SERVICING THE FLOOR FURNACE, TURN OFF THE GAS AND ALLOW IT TO COOL.
THIS WILL PREVENT BURNS.
ALWAYSLEAVE THE GRILL IN PLACE EXCEPT WHEN CLEANING OR SERVICING THE FLOOR IAIRNACE.
NEVER OPERATE THE FLOOR FURNACE WITHOUT THE SIGHT GLASS ASSEMBLY IN PLACE, OR WITH
THE GLASS BROKEN OR MISSING.
HELPFUL INSTALLATION INFORMATION
Do not attempt to heat through more than one doorway in any direction to adjoining rooms.
Always over-estimate the amount of heat required rather than under-estilnate it. Always use the next size floor furnace above
your actual heating requirements.
Seal all cracks around windows, doors, and attic access doors or siNfificant heat loss will occur.
INSTALLATION REQUIREMENTS
Listed below are steps that are part of a floor furnace installation. You must see that each step is followed closely so that the
floor furnace wilt provide lnaxilnum efficiency with safe operation.
YOU MIYST:
1. Locate the floor furnace in the best available space for safe and efficient operation.
2. Provide fiesh air for combustion and venting.
3. Cut and fiame the floor opening so that the floor furnace fits properly.
4. Attach the draft hood and connect the vent pipe in compliance with applicable codes.
5. Connect an adequate gas supply to the floor furnace.
6. Select the best location for the thermostat.
7. Check and adjust the floor furnace for safe and efficient operation.
If you have any doubts about the correct way to install a floor furnace, contact local authorities or agency, or your gas supplier.
If locat or state codes require that your floor furnace installation be inspected by local authorities, do so after the floor furnace
is installed and before it is put into selMce.
Page 3