Country Home Products DR Vacuum Cleaner User Manual


 
38 DR
COMMERICAL LEAF and LAWN VACUUM Safety & Operating Instructions
Removing and Replacing the Blower Exit Elbow
Tool Needed:
Diagonal or wire cutter
WARNING! Before performing any maintenance procedure, stop the
engine and disconnect the spark plug wire.
Wing
Screw
4-places
Lift Off
Collector Box Hose
Blower Exit
Elbow Assy
Flexible Latch
Figu
r
e 44
Safety
Interlock
Switch
1. Disconnect the Blower Exit Elbow to
the Collector Box Hose by releasin
g
the two flexible latches (Figure 44) and
separate the hose.
2. Cut the tie around the Inlet Hose a
t
the end of the Lanyard (Figure 43).
3. Remove the four (4) Wing Screws
from the Blower Exit Elbow Assembl
y
(Figure 44).
4. Lift the Blower Exit Elbow Assembl
y
from the top of the Blower and install
a new assembly in the reverse orde
r
(Figure 44).
5. Install the new cable tie through the
end loop of the Lanyard about halfwa
y
along the Blower Inlet Hose.
6. Check the Safety Interlock Switch to
be sure that it is engaged.
Note: If the safety interlock switch is no
t
engaged, adjust the switch
mounting bracket by loosening the
bracket bolt and sliding the bracke
t
up so that the button on the switch
is fully depressed against the
blower exit elbow assembly. See
page 16.
Angle
Adjusting
Wing Screw
2
p
laces