Country Flame DV 46 Stove User Manual


 
GENERAL VENT INSPECTION
Inspect the venting system periodically. Additional areas to inspect are as follows:
1. Check areas of the venting system which are exposed to the elements for corrosion. These will appear as
rust spots or streaks, and in extreme cases, can be holes. These components must be replaced to ensure the
integrity of the system and the safety of the homeowner.
2. Remove the chimney cap and shine a flashlight down the vent. Remove all debris, bird nests, or other
foreign material found in the vent system.
3. Check for evidences of excessive condensate, such as water droplets forming in the inner liner, and
subsequently dripping out of vent joints. Continuous condensate can cause corrosion of caps, pipe and
fittings. Condensation may be caused by having excessive horizontal runs, too many elbows, and exterior
portions of the system being exposed to cold weather. Consult a certified professional to correct.
4. Inspect joints, to verify that no pipe sections or fittings have been disturbed or consequently loosened.
Also check mechanical supports such as wall straps or plumbers' tape for proper integrity/support.
5. For all direct vent systems, proper re-assembly and resealing of the vent-air intake system is mandatory.
If the vent-air system is disassembled for any reason, reinstall each part per instruction provided for the
initial installation.
GENERAL CLEANING
General cleaning of the appliance should be completed routinely to remove all dust, lint, or other debris that
has built up during non-use in the off season. The three burners should be cleaned per specific tasks listed
in this manual. The burners can be blown out with dry air or be vacuumed to remove dust or other debris.
If any burners look to be damaged or degraded in appearance, contact a certified professional to verify their
working order.
No lubrication of any part is required in the Bayvue DV appliance. It is recommended that at a minimum,
annual inspection of the venting system be conducted by a certified professional. At no time should the
combustion air or ventilation air of this appliance be allowed to become obstructed. Free airflow is crucial
to the proper operation of this appliance. The pilot and burner should be checked for proper flame pattern.
Flame patterns should not appear to be suspended about the pilot tube or the burners. Nor should the pilot
or burner flame appear lifeless or smoking in its burn pattern. Have the operational burn patterns checked
by a certified professional in the event there is any question about gas burn patterns. Do not use this
appliance if any part or component of this appliance has ever been under water. Immediately call a certified
professional to inspect or replace any part or control system that has been under water.
GENERAL SAFETY
-Always shut off the gas supply and allow the heater to cool down before attempting any service work.
-Always check for leaks, after servicing.
-Always check for correct combustion and ventilation air flow after performing any service.
-Always make sure the heater is away from any combustible or flammable materials.
-Always ensure proper re-assembly and re-sealing of all vent-air intake parts. If any part of the system is
disassembled, reinstall those parts per the instructions provided in this manual.
GENERAL PERIODIC INSPECTIONS
Check the venting system annually and make sure the system is clear of any debris.
Check flame patterns periodically.
Allow 15 minutes for the flame to reach maximum color and height.
CLEANING A PAINTED SURFACE
Occasionally dry rag dust to keep the painted surface looking new. Paint can be touched up as needed.
Clean the areas to be painted with fine steel wool. Remove all trim or cover all trim and controls with
masking tape. Then, touch up the stove with Stove Bright
®
high temperature stove paint.
Version 1.0h
36