Country Flame DV 46 Stove User Manual


 
CHECK FLAME AND PILOT
FREQUENCY: Periodically.
PERFORMED BY: Qualified service technician or homeowner.
TASK PERFORMED: Visually inspect the three burner’s flame height and burn patterns. The front burner
flame will be barely visible through the glowing embers. The middle and back burner flames are steady and
not lifting or floating from away from the burner surfaces. Refer to FIGURE 5d for a picture representation
of the proper flame with logs and embers installed. Visually inspect that the pilot light is burning with four
blue flame nodes, FIGURE 21, protruding from the pilot flame diffuser, FIGURE 21, Item B. There should
be no sputter or blockage of any of the pilot flame or its four flame nodes. There should be a blue flame
surrounding the outside edge of the pilot flame diffuser, FIGURE 21, Item B. In the event any abnormality
is observed in the burner flame pattern or the pilot light flame pattern, contact a local authorized Country
Flame Dealer or certified technician.
FIGURE 21: STANDING PILOT
GLASS CLEANING
FREQUENCY: Before the first use and after first four hours of use the glass should be cleaned; thereafter,
clean as necessary.
PERFORMED BY: Homeowner.
TASK PERFORMED: Remove the door assembly by unhooking the four locks (2 locks on each side).
Use a household glass cleaner or a Hearth Industry approved gas stove glass cleaner. Replace the door
assembly and close the four locks to properly seal the door to the body of the Bayvue DV.
CHECK VENT SYSTEM
FREQUENCY: Once during annual inspection. See General Inspection for additional requirements.
PERFORMED BY: Qualified service technician or homeowner.
TASK PERFORMED: Check complete vent system for corrosion, moisture problems, pin holes or broken
seals. Remove chimney cap and inspect vent and cap for debris. Ensure clean and open vent system.
Version 1.0h
33
WARNING: DO NOT ATTEMPT TO CLEAN GLASS UNTIL APPLIANCE IS COOL
WARNING: DO NOT USE ABRASIVE CLEANERS ON GLASS SURFACE