Country Flame DV 46 Stove User Manual


 
FIGURE 12: BLOWER FAN
FAN INSTALLATION
The Bayvue DV comes standard with the fan kit installed. The Fan Kit consists of a blower system. The
fan is connected to the Bayvue DV’s wiring harness. The Bayvue DV is pre-wired for and includes a
rheostat (speed control), a heat activated thermo-disc and a 120 volt receptacle. The fan slips inside the
back of the pedestal into two slides mounted to the bottom of the firebox.
DIRECT VENT INSTALLATION
GENERAL
Country Flame Bayvue DV product is approved for side wall vent or vertical vent through a roof. Only
Simpson Dura Vent chimney components or Selkirk Model Direct-Temp chimney components may be
used with this product. Simpson Dura Vent chimney vent products are listed in this manual to assist with
vent installation selection. Read all these instructions carefully before starting the installation. Failure to
follow instructions may create a fire or other safety hazard, and will void the product warranty. Be sure to
follow installation instructions and maintain proper venting and maintain clearances to combustible that
will vary from one installation to another.
Version 1.0h
19