OPERATING FIREPLACE
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise to the OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information above. If you don’t smell
gas, go to the next step.
Ignitor Button
Figure 30 - Control Knob In The OFF Position
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
Control
Knob
WARNING: You must operate this fireplace with
the fireplace screen in place. Make sure fireplace
screen is installed before running fireplace.
NOTICE: During initial operation of new fireplace,
burning logs will give off a paper-burning smell.
Orange flame will also be present. Open window to
vent smell. Operate fireplace on HI position to burn off
odor. This will only last a few hours.
5. Turn control knob counterclockwise to the PI-
LOT position. Press in control knob for five (5) seconds
(see Figure 30).
Note:
You may be running this fireplace for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ig-
nitor button. This will light pilot. The pilot is attached to
the front of burner. If needed, keep pressing ignitor but-
ton until pilot lights.
Note:
If pilot does not stay lit, refer to Troubleshooting, pages
20 through 22. Also contact a qualified service person or gas
supplier for repairs. Until repairs are made, light pilot with
match. To light pilot with match, see Manual Lighting Pro-
cedure, page 18.
7. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7. This fire-
place has a safety interlock system. Wait one (1) minute
before lighting pilot again.
8. Turn control knob counterclockwise to desired
heating level. The main burner should light. Set control
knob to any heat level between HI and LO.
Thermocouple
Pilot Burner
Figure 31 - Pilot
Ignitor Electrode
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
OPERATING FIREPLACE
For Your Safety Read Before Lighting
Lighting Instructions