• A Type 1 compatible cylinder with a Type 1
cylinder valve has a back-check valve which
does not permit gas flow, until a positive seal has
been obtained.
• The cylinder must be arranged in an upright
position for vapor withdrawal. It must also include
a collar to protect the cylinder valve. A safety
relief device having direct communication with
the vapor space of cylinder must be provided.
This will expel high pressure gas if the cylinder is
over filled or overheated which could result in fire
or explosion.
• All refillable L.P.gas cylinders used with this
appliance shall be constructed and marked in
accordance with the Specifications f
or L.P.Gas
Cylinders of the U. S. Department of
Transportation (DOT) or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres
and Tubes f
or Transportation of Dangerous
Goods; and Commission, as applicable; and shall
be provided with a listed overfilling prevention
device, and a cylinder connection device
compatible with the connection for outdoor
cooking appliances.
• Read labels on the L.P.Gas Supply Cylinder.
• New refillable cylinders are always shipped
empty for safety.
• Allow only qualified L.P.gas dealers to fill or
repair your refillable L.P.gas supply cylinder.
• Inform the gas dealer if it is a new or used
cylinder to be filled.
• Caution the gas dealer not to overfill the cylinder.
• After filling, have the gas dealer check for leaks
and to see that the relief valve remains free to
function.
The Type 1 connection system has the following
features:
1.The system will not allow gas to flow until a
positive connection has been made.
NOTE: The cylinder control valve must be turned
off before any connection is made or removed.
2.The system has a thermal element that will shut
off the flow of gas in the event of a fire.
3.The system has a flow limiting device which,
when activated, will limit the flow of gas to 10
cubic feet per hour.
4. NEVER use stove without leak testing this
connection.
CAUTION
Have the gas dealer weigh the cylinder
after filling to ensure that the cylinder is
not over filled.
Hose and Regulator
The pressure regulator and hose assembly with
the Type 1 fitting supplied with the appliance must
be used. Do not use another hose and regulator
assembly other than the one supplied with the
stove or a Coleman® replacement pressure
regulator assembly.The pressure regulator and
hose assembly provided is factory set at an outlet
pressure of 11 inches water column (1/2 psi).
• Keep the small vent hole in the regulator clean of
dirt and debris (see item [G], Fig. 21).
• Consult your L.P.gas dealer if you think the
regulator is not working properly.
WARNING
• DO NOT attempt to adjust the regulator as
this could create a situation causing
personal injury or property damage.
• Transport only one refillable cylinder at a time.
• Transport the cylinder in an upright and secure
manner with a control valve turned off and the
cap in place.
• DO NOT transport the cylinder in the passenger
compartment, unless you have an open window
ventilation.
• DO NOT leave the cylinder in direct sunlight or in
a high heat area such as a closed car trunk. High
heat areas could cause the relief valve to vent
gas.
• Use a cylinder cap on the cylinder valve outlet
during transport and when the cylinder is not
connected to the stove.
• Keep the cylinder valve closed when not in use.
• Take the cylinder directly home after it has been
filled.
Transporting the Refillable
Cylinder
WARNING
Handle a full cylinder with care. Gas is under
high pressure.
DANGER
• NEVER store a spare L.P. gas supply cylinder
in the vicinity of any heat producing
appliance.
• NEVER fill the cylinder beyond 80% full.
Failure to follow this information exactly could