Operation
-10- COLORado™ 1 IP User Manual Rev. 01c
Continued from previous page
DMX Control With ID
Addressing
In this mode, the fixtures with the same DMX starting address will respond to the DMX
controller based on the fixture’s individual ID address setting. If the user selects ID
address “0”, all the fixtures with the same DMX address will respond in unison.
Otherwise, each fixture will follow the control for its particular ID address.
1) Repeat steps 1, 2, and 3 from DMX Control Without ID Addressing.
2) Activate ID Addressing in each fixture:
a) Go to SET > ID.
b) Select ON.
3) Select an ID address for each fixture:
a) Go to ID.
b) Select an ID (01~66)
Static Color
The Static Color mode allows for permanent RGBW color mixing without a DMX
controller.
1) Go to STAT.
2) Select the desired color (Red, Green, Blue, or White).
3) Select the desired color value (0~255).
4) Repeat for the other colors.
5) Select Strob.
6) Select the desired frequency (0~20).
Auto Programs
Auto programs allow for dynamic RGBW color mixing without a DMX controller.
1) Go to AUTO.
2) Select the desired auto program (AT. 01~10 or PR. 01~10).
You cannot edit auto programs AT. 01~10. However you can edit PR. 01~10 (see
Edit Customs).
Edit Customs
This setting allows for the programming of up to 30 scenes for each of the 10
customizable programs, including colors and effects.
1) Go to EDIT.
2) Select the desired auto program (PR. 01~10).
3) Select the desired scene (SC. 01~30).
4) Select the desired color or effect (Red, Green, Blue, White, Strobe, Time, or
Fade).
5) Select the desired value for the color or effect (000~255 for colors and timers, or
00~20 for Strobe).
6) Repeat for the other colors or effects.
7) Repeat for the other scenes.
Master/Slave
The Master/Slave mode allows a group of COLORado™ 1 IP
fixtures (the slaves) to
execute simultaneously the same program, whether auto or custom, that another
COLORado™ 1 IP fixture (the master) is executing, without a DMX controller.
1) Set the Master Unit:
a) Set the running mode to DMX as explained in “DMX
Control Without ID
Addressing”.
b) Select an auto program as explained in “Auto Programs”.
2) Set the slave units:
a) Go to RUN.
b) Select SLAV.
• The fixture that runs an auto program automatically becomes the Master.
• Do not connect a DMX controller to the master or slave fixtures.
Continues on the next page