INSTALLATION STEP 7
Electrical Requirements
To avoid installation difficulties, do not run the
opener at this time.
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third grounding
pin. This plug will only fit into a grounding type outlet. If
the plug doesn't fit into the outlet you have, contact a
qualified electrician to install the proper outlet.
RIGHT
WRONG
If permanent wiring is required by your local code,
refer to the following procedure.
To make a permanent connection through the 7/8" hole
in the back of the motor unit (according to local code):
• Remove the opener from the torsion bar, remove cover
screws and set the cover aside.
• Remove the attached green ground terminal.
• Cut black and white wires and strip away 1/2" (1.3 cm)
of insulation, 3" (7.6 cm) before spade terminals.
• Remove the power cord from unit.
• Install a 90
o
conduit or flex cable adapter to the 7/8"
hole. Reinstall opener to torsion bar.
• Run wires through conduit, cut to proper length and
strip insulation.
• Attach with wire nuts provided.
• Properly secure wire under plastic ties so that wire
does not come in contact with moving parts.
• Reinstall the cover.
To avoid installation difficulties, do not run the
opener at this time.
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
• Be sure power is not connected to the opener, and
disconnect power to circuit BEFORE removing cover to
establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance
with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter or change
plug in any way to make it fit outlet. Be sure the opener is
grounded.
PERMANENT WIRING CONNECTION
Flexible conduit
Green
Ground
Screw
Ground Tab
Ground Wire
Black Wire
From Pow
er Cord
White Wire
From Power Cord
PERMANENT WIRING CONNECTION
Black Wire
Green Wire
White Wire
90˚ Connector
12