Pyromaster© H33BDVRRN/P
10004798
Troubleshooting – Honeywell VS8421
START CHECK
Remove Glass Doors Before Service Work
GAS SUPPLY ON
▼
▼
▼
▼
▼
PILOT LIGHTS WITH
PIEZO IGNITOR
• Lockout Has Engaged. Wait 60
Seconds And Try Again.
• For Spark At Electrode While
Depressing Piezo
1/8" Gap To Pilot Hood Needed.
• All Wiring Connections
• Replace Piezo Ignitor
• Supply Line Hooked Up
• Shutoff Valve Open
PILOT STAYS LIT
• For Air In The Lines
• Thermopile Needs A Min.
325mv. Adjust Pilot Flame
Height.
• All Wiring Connections
• Replace Thermopile
• Thermocouple Needs A Min. Of
14mv
• Defective Valve. Turn To Pilot,
Meter Should Read Greater
Than 100mv. If Not, Replace.
PILOT LIGHTS MAIN
BURNER
• Valve Is Turned On
• Wall Switch Is Not Turned On.
Watch For Grounded Wires!
• Thermopile Needs A Min. 325mv.
• Plugged Burner Orifice
SYSTEM OK
▼
YES
NO
NO
▼
NO
▼
NO
YES
YES
YES